Commercial Exit & Emergency Lighting Services Melbourne

#1 Rated Electricians with 400+ Google Reviews

Contact Us 0447 139 493

Book in For A Quote!
Ask About Our FREE Electrical Inspections

Emergency Exit Lighting That Works When Power Fails

In the middle of an emergency, clarity counts. Smoke thickens, panic rises, and visibility vanishes, this is when exit and emergency lighting becomes the difference between calm evacuation and confusion.

At Electrx, we install and maintain exit and emergency lighting systems that meet full compliance with AS/NZS 2293 standards and the National Construction Code (NCC). From warehouses to retail precincts, we specialise in commercial lighting solutions that prioritise safety, durability, and energy efficiency.

Exit Lighting
Exit Lighting(3)
Exit Lighting(4)

Why Choose Us For your Emergency Exit lighting

Exit Lighting(3)

Expertly Designed Lighting Systems for Commercial Buildings

Emergency lighting isn’t one-size-fits-all. Electrx leverages industry-leading products and technical design insight to deliver custom lighting setups that are clear, compliant, and optimised for every environment.

We assess your site layout, occupancy flow, and building use to strategically position:

  • Exit signs above all designated doors and pathways
  • Emergency lighting throughout corridors, stairwells, and open-plan areas
  • Directional indicators in complex floor plans and split-level sites
  • Accessibility exit signage for compliant evacuation routes
  • Battery-backed or self-charging systems for blackout resilience
  • Energy-efficient LED upgrades that lower costs and boost reliability

From new installations to retrofits and upgrades, we take care of everything, right down to compliant mounting heights and photometric spacing.

GET A FAST CALL BACK

GET AN ELECTRICIAN TODAY

Contact Us 0447 139 493

Where Emergency Lighting Is Essential

Every commercial site has its own escape challenges. That’s why we ensure effective coverage in:

  • Retail centres and showrooms
  • Warehouses and logistics facilities
  • Office buildings and commercial tenancies
  • Car parks and outdoor exit paths
  • Lift lobbies and stairwells
  • Server rooms, kitchens, and storage zones
  • Public access spaces like reception areas or break rooms
  • Utility and plant rooms

Lighting isn’t just about exit doors, it’s about leading people clearly and calmly to safety from any point in the building.

Our Emergency Lighting Services

  • New System Design & Installation
  • Scheduled Testing & Logbook Management
  • Maintenance & Battery Replacement
  • Compliance Upgrades & Certification
  • Fault Repairs & Emergency Callouts
  • Beacon Lighting Product Integration

We ensure every fitting, sign, and test meets Australian Standard requirements and is supported by full documentation for audit or insurance purposes.

Stay Compliant, Stay Covered

Regulations demand more than a glowing sign. Emergency lighting must:

  • Stay illuminated for at least 90 minutes during power failure
  • Be tested monthly and discharge-tested annually
  • Remain clearly visible from all escape routes
  • Maintain performance even in adverse conditions

Neglecting these requirements could lead to serious liability, fines, or insurance complications—not to mention increased risk for staff or tenants.

With Electrx, you get a team of commercial electricians that understands both the letter and spirit of compliance. We’re here to ensure your lighting systems are not only installed right—but maintained to perform when it counts.

Book an Emergency Lighting Inspection or Upgrade

Need a compliance check? Time for a system upgrade? Call Electrx to discuss your project. As Beacon Lighting preferred electricians, we’ll match trusted products with professional service—for peace of mind when the power goes out.

Frequently Asked Questions

In Victoria, emergency and exit lighting in Class 2 to Class 9 buildings must comply with the AS/NZS 2293.1 standard. Systems must remain illuminated for a minimum of 90 minutes during a power failure and undergo regular function and discharge testing. Building owners are legally responsible for ensuring systems remain compliant and operational.

Emergency lighting systems must be function tested monthly and undergo a full 90-minute battery discharge test at least once a year. These tests should be recorded in a logbook to ensure compliance with Australian safety regulations and insurance requirements.

Emergency lights must be installed above all exit doors and along evacuation paths, including corridors, stairwells, ramps, lift lobbies, and large open areas. Additional lighting is required at points where escape routes change direction, and near fire safety equipment, restrooms, plant rooms, and car parks.

es. As Beacon Lighting preferred electricians, Electrx specialises in upgrading older systems to energy-efficient LED emergency lighting. These modern solutions reduce energy costs, improve performance, and extend operational life—all while keeping your building compliant with current safety standards.

Ready to Book An Electrician?

Every client matters to us, and we look forward to helping you with any electrical work

0447 139 493